Company | Reagent | Link to information | Remarks |
BioMedica Diagnostics | ACTICLOT Protein S |
Method: Clotting |
|
Hyphen BioMed | Hemoclot Protein S | Hyphen Hemoclot protein S |
Method: Clotting Assay principle: APTT based, triggered by Factor IXa in the presence of APC Interferences: Heparin > 1.0 IU/ml, interference expected from abnormal high levels of FVIII:C, Lupus, FV Leiden and in aprotinin treated patients |
Precision Biologic | Cryocheck Clot S | Precision Biologic Cryocheck Clot S |
Method: Clotting Assay principle: Measurement of free protein S Interferences: Factor VIII:C levels >600% and unfractionated heparin/ low molecular weight heparin > 1.0 IU/ml |
r2 Diagnostics | Thrombo Tek PSe | r2 Diagnostics Thrombo Tek PSe | Method: Clotting
Assay principle: Measurement of free protein S Interferences: Heparin > 1.0 IU/ml |
Siemens Healthineers | Protein S Ac | Siemens Protein S Ac | Method: Clotting
Assay principle: Measurement of free protein S Interferences: Heparin > 3.0 IU/ml andFactor VIII:C levels >400% |
Stago | STA-Staclot Protein S | Stago STA-Staclot ProteinS |
Method: Clotting Assay principle: Measurement of free protein S |
Stago, Tcoag | TriniCLOT Protein S II | Stago TriniCLOT Protein S II |
Method: Clotting Assay principle: Measurement of free protein S |
Technoclone | Technoclot Proetein S | Technoclone Technoclot Protein S |
Method: Clotting |
Werfen | HemosIL Protein S Activity | Werfen HemosIL Protein S Activity |
Method: Clotting Assay principle: Measurement of free protein S Interferences: Heparin UF > 1.6 IU/ml and heparin LMWH > 2.1 IU/ml |
- Special Information
- Calendar
- Assays
- Fibrinogen
- APTT
- Factor IX chromogenic methods
- PT/INR
- Antithrombin activity
- Antithrombin antigen
- Protein C activity
- Protein C antigen
- Protein S activity
- Protein S antigen (Free)
- Protein S antigen (Total)
- Activated protein C resistance ratio
- Protein C pathway test
- Lupus anticoagulant
- Antiphospholipid antibodies (Anticardiolipin)
- Antiphospholipid antibodies (α2-Glycoprotein I)
- D-Dimer
- Activator VIII IX XI XII
- Deficient plasma VIII IX XI XII
- Factor IX antigen
- Calibrators VIII IX XI XII
- Factor VIII antigen
- Factor VIII chromogenic methods
- Activator II V VII X
- Prothrombin (factor II) chromogenic methods
- Deficient plasma II V VII X
- Calibrators II V VII X
- VWF antigen
- VWF collagen binding assay
- VWF multimers
- VWF Activity
- VWF:RiCoF
- Factor XIII activity
- Factor XIII antigen
- Factor VIII deficient plasma
- Normal pooled plasma
- Immunological test
- Plasminogen activity
- Plasminogen antigen
- Plasmin inhibitor activity
- PAI-1 antigen
- PAI-1 activity
- t-PA antigen
- t-PA activity
- Method homocysteine