Company | Reagent | Link to information | Remarks |
Chromogenix | Coamatic Antithrombin | Reagent: Lyophilized
Method: Chromogenic Assay principle: Anti Xa |
|
Chromogenix | Coamatic LR Antithrombin | Reagent: Liquid
Method: Chromogenic Assay principle: Anti Xa |
|
Helena Biosciences | Antithrombin Xa | Reagent: Lyophilized
Method: Chromogenic Assay principle: Anti Xa |
|
Hyphen BioMed | Biophen Antithrombin | Hyphen Biophen Antithrombin | Reagent: Lyophilized
Method: Chromogenic Assay principle: Anti Xa Interferences: No interference of heparin, heparin Cofactor II, alpha-2-macroglobulin or alpha1-Antitrypsin.No significant interference for haemoglobin < 2.5 mg/ml, and bilirubin < 0.1 mg/ml |
Hyphen BioMed | Biophen AT anti-(h)-Xa LRT | Hyphen Biophen AT anti-(h)-Xa LRT | Reagent: Liquid
Method: Chromogenic Assay principle: Anti Xa Interferences: No interference of heparin, heparin Cofactor II, alpha-2-macroglobulin or alpha1-Antitrypsin.No significant interference for haemoglobin < 2.5 mg/ml, and bilirubin < 0.1 mg/ml |
Hyphen BioMed | Biophen AT (anti-lla) | Hyphen Biophen AT (anti-lla) | Reagent: Lyophilized
Method: Chromogenic Assay principle: Anti IIa Interferences: No interference of heparin (UFH, LMWH) at usual therapeutic doses |
Hyphen BioMed | Biophen AT (LRT) | Hyphen Biophen AT (LRT) |
Reagent: Liquid Method: Chromogenic Assay principle: Anti Xa Interferences: No interference of heparin, heparin Cofactor II, alpha-2-macroglobulin or alpha1-Antitrypsin.No significant interference for haemoglobin < 2.5 mg/ml, and bilirubin < 0.1 mg/ml |
Nordic Biomarker | MRX Antithrombin |
Reagent: Liquid Method: Chromogenic Assay principle: Anti Xa |
|
Renam | Reachrom-ATIII |
Method: Chromogenic |
|
Renam | Reaclot-ATIII |
Method: Clotting |
|
Roche | AT | Roche AT |
Reagent: Liquid Method: Chromogenic Assay principle: anti IIa |
Siemens Healthineers | Berichrom Antithrombin III | Siemens Berichrom Anthitrombin III |
Reagent: Lyophilized Method: Chromogenic Assay principle: Anti Xa Inteferences: Therapeutic doses of hirudin or other direct thrombin inhibitors will cause erroneously |
Siemens Healthineers | Innovance Antithrombin | Siemens Innovance Antithrombin |
Reagent: Liquid Method: Chromogenic Assay principle: Anti Xa Interferences: No interference of heparin < 2 U/ml, heparin cofactor II < 400 mg/L, hirudin < 5 mg/L, therapeutic doses of oral direct factor Xa inhibitors may cause erroneously increased |
Stago | STA-Stachrom AT III | Stago STA-Stachrom AT III |
Reagent: Lyophilized Method: Chromogenic Assay principle: Anti IIa Interferences: No interferences of therapeutic doses of heparin, hemoglobin < 7 g/l, bilirubin < 200 mg/l, |
Stago, Tcoag | TriniCHROM Antithrombin lla | Stago TriniCHROM Antitrombin IIa |
Method: Chromogenic Assay principle: Anti IIa Interferences: Interference of heparin cofactor |
Stago, Tcoag | TriniCHROM Antithrombin Xa | Stago TriniCHROM Antitrombin Xa |
Method: Chromogenic Assay principle: Anti Xa Interferences: No interference of heparin cofactor II |
Technoclone | Technochrom ATIII kit | Technoclone Technochrom ATIII kit | Method: Chromogenic
Assay principle: Anti IIa |
Technoclone | Technochrom ATIII manual method kit | Technoclone Technochrom ATIII manual method kit | Method: Chromogenic
Assay principle: Anti IIa |
Werfen | HemosIL Antithrombin | Werfen HemosIL Antithrombin |
Reagent: Lyophilized Method: Chromogenic Assay principle: Anti Xa Interferences: No interference of (UF heparin or LMW |
Werfen | HemosIL liquid Antithrombin | Werfen HemosIL liquid Antithrombin |
Reagent: Liquid Method: Chromogenic Assay principle: Anti Xa Interferences: No interference of heparin (UF heparin or LMW |